Distributors Digi-key Thomatronik Newark IBS Electronics

Inrush Current Limiters - Power Thermistors

Inrush Current Limiter - Power Thermistor
Power Thermistor Data
Input Voltage Inrush Current Limiter
Up To 120vac SL03 - SL10 Series
Up To 240vac SL10 - SL32 Series
Up To 480vac MS15 - MS32 Series
Up To 680vac MS22 - MS35 Series
   
Full Line SL03 - MS35
UL & CSA Recognized UL & CSA - SL Series
Inrush Current Power Thermistor Chart
Inrush Current Info
Inrush Current Limiters
Power Electronics article on applications of inrush current limiting thermistors - Power Thermistors
Inrush Current FAQ
Frequently Asked Questions about inrush current limiting thermistors -Power Thermistors
Inrush Current in Transformers
A sample application of inrush current limiters in transformers.
Inrush Current Causes and Prevention
A summary of what causes inrush current and how it can be addressed.
How To Select An Inrush Current Limiter
 More Detailed explanation of selecting an inrush current limiter -Power Thrmistor.
Thermal Time Constant
What is the thermal time constant of an inrush current limiter.
Select an Inrush Current Limiter - Power Thermistor

Step1)
Use the maximum allowable inrush current and Ohm's Law to determine the least allowable resistance at turn on for your application.

V*1.414/A
Input Voltage
Max Inrush (A)
Lowest Resistance  
Needed

Step 2)
Determine the maximum steady state current that will flow through the Inrush Current Limiter.

 Vac/P(out) * 90% efficiency
Output Power        
Input Voltage
Steady State
Current

Step 3)
Using the formula 
J = ½CV², determine how much input energy the thermistor will absorb when the device is turned on.

Inrush Energy (Joules)
Voltage (peak)
Capacitance in µF   
Total Energy
(Joules)

Step 4)

Select a part from this list or any of the links to datasheets and get samples or click on a link to get it from one of our worldwide partners.
Part Resistance SSI Max Max
Joules
Max cap
120 vac
Max cap
240 vac
Max cap
440 vac
D Max
(mm)
T Nom
(mm)
Digikey Newark Farnell
SL03 10001 10.0 1 2 100     3 3 570-1088-ND 72J6655 9006400
SL10 10002 10.0 2 10 700 135   10 5 72J6710 9006966
SL10 10003 10.0 3 17 1,100 300   10 5 570-1082-ND 72J6711 9006974
SL10 10004 10.0 4 17 1,100 300   10 5 72J6712 9006982
SL18 10005 10.0 5 75 3,400 850   19 6 570-1068-ND 72J6808 9007962
SL12 10006 10.0 6 40 2,700 960   13 6 570-1078-ND 72J6734 9007202
SL15 10006 10.0 6 55 780     16 6 72J6769 9007563
SL22 10008 10.0 8 90 6,000 1,250   22 5 570-1034-ND 72J6819 9008071
MS22 10008 10.0 8 200 13,850 3,400 1,000 23 10 570-1003-ND 72J6608 9005935
SL32 10015 10.0 15 150 10,380 2,600   31 6 570-1058-ND 72J6844 9008322
MS32 10015 10.0 15 250 19,250 4,300 1,250 31 9 570-1014-ND 72J6620 9006052
MS35 10018 10.0 18 500 34,000 8,600 2,500 37 11 570-1024-ND 72J6630 9006150